Medical Laser Equipment Power Supplies

Precision Power for Therapeutic and Surgical Laser Systems

Horizon PSS designs custom and semi-custom power supplies specifically engineered for surgical lasers, ophthalmic lasers, dermatology platforms, and therapeutic laser devices. Power solutions address energy dose precision, beam quality stability, thermal management for continuous-wave operation, and IEC 60601-1 compliance for solid-state, diode, and gas laser systems.

Find Your Product

Product
Type
Power
Input Voltage
Output Voltage
Action
No results

Meeting Engineering, Procurement and Compliance Needs

Custom Power Architectures for Laser Performance
Delivering energy dose precision better than 0.1% with shot-to-shot repeatability ensuring consistent tissue ablation depth and therapeutic effect across thousands of pulses.

Maintaining beam quality through ultra-low noise power (<10 mV ripple) preventing mode hopping, spatial beam distortion, and wavelength drift during surgical procedures.

Managing thermal load and repetition rate stability for continuous-wave and high-duty-cycle operation without power degradation or thermal runaway affecting treatment outcomes.
Standards Compliance Built Into the Design
Incorporating 2x MOPP isolation for patient-applied parts with leakage current control maintaining safety during beam-on conditions. Building IEC 60601-1 core safety compliance throughout product lifecycle.

Integrating emergency stop response, laser emission interlocks, and fault condition shutdown specific to surgical laser operation. Meeting IEC 60601-2-22 requirements with interlock monitoring preventing accidental beam exposure.

Supporting key switch control, enable signal sequencing, and capacitor discharge provisions for safe beam termination. Integrating IEC 60825 laser safety classification requirements.

Passing EMI testing ensuring power delivery doesn't introduce noise affecting adjacent surgical monitors or anesthesia equipment. Meeting IEC 60601-1-2 EMC compliance.
Application-Specific Engineering
Providing high-efficiency pump current for flashlamp and diode-pumped solid-state lasers (Nd:YAG, Er:YAG, Ho:YAG) with flashlamp aging compensation and end-of-life detection preventing beam degradation.

Delivering constant-current regulation with thermal coefficient compensation for diode laser arrays, managing forward voltage variation across strings and preventing cascade failures that compromise beam uniformity.

Supplying high-voltage RF power for CO₂ laser excitation with gas pressure-compensated control maintaining beam quality and preventing mode instability during power modulation.

Managing capacitor charging, high-voltage switching, and pulse-forming networks for Q-switched and pulsed systems with precise energy delivery and repetition rate stability ensuring consistent ablation per pulse.
Custom Development Process for OEM Programs
Characterizing laser electrical profiles including pulse energy, repetition rate, duty cycle, and thermal dissipation with transparent NRE structures defining specifications and compliance pathways.

Integrating thermal management for pump diodes, laser rods, and power electronics preventing beam quality degradation during extended procedures.

Coordinating interlock signals, enable sequences, and capacitor discharge timing with your laser controller ensuring safe beam control and preventing accidental exposure.
RFI/RFQ Support for Procurement Teams
Supporting procurement evaluation with energy dose stability data (joules per pulse variation), beam quality test results, thermal performance across duty cycles, pulse timing jitter specifications, flashlamp aging compensation data, isolation test certificates (2x MOPP), and interlock response timing.
Why Medical Laser OEMs Choose Horizon PSS
IEC 60601 and IEC 60825 compliance responsibility is integrated into power system architecture development with interlock safety verification.

Engineering depth encompasses laser physics, pump efficiency optimization, thermal load management, and energy dose control for predictable tissue interaction.

Production capability and design documentation are maintained throughout your product lifecycle supporting flashlamp replacement cycles and platform upgrades.

Custom power design eliminates beam quality degradation, energy dose variation, and thermal drift affecting surgical outcomes.

Contact our experts for Custom Medical Laser Equipment power solutions

Ready to discuss your medical laser power requirements? Request an engineering consultation or submit an RFI with your system architecture, power budgets, and regulatory requirements.

This field is for validation purposes and should be left unchanged.

By submitting this form, you consent to Horizon storing and processing the personal information provided in accordance with our Privacy Policy

Resources

Explore in-depth resources, including case studies, white papers, and blog posts on Horizon’s Medical power supply solutions.

Accessibility
Reset
Big Cursor (Black)
Big Cursor (White)
Enlarge Window
Larger Font
Smaller Font
Readable Font
Monochrome
Dark Contrast
Light Contrast
Highlight Links
Highlight Headers
Images Description
Keyboard Navigation
Disable Flicker
Powered by Emilia Digital